The water quality in cooling towers can often degrade, creating a bevy of negative environmental consequences as well as a long list of liabilities and expenses for the business using them. However, many water treatment systems are expensive and result in water with high chemical contents. That’s not the case, though, when you use ozone water treatment systems.

Ozone Pure Water Inc. provides ozone cooling tower water treatment systems to treat and purify water without the need for extra maintenance, expense or chemicals. By using the oxidation process naturally occurring with the use of ozone, dangerous compounds are eliminated from the water without the need to constantly change your cooling tower equipment or resupply harmful elements for chemical treatment.

The ozone water treatment system reduces or eliminates the need for chemical dependence in cooling towers, thereby also reducing total dissolved solids (TDS) levels in the water. This, in turn, reduces the need to continually drain and replenish water and reduces overall water waste. The ozone treatment system removes organic materials, bacteria and viruses and reduces scale build-up over time using a relatively simple process that does not require significant changes to the cooling towers or peripheral equipment.

While corrosion has been an obstacle to ozone treatment systems in the past, we design treatment systems to introduce stable levels of ozone into the water. This eliminates the corrosion risk to sumps and other equipment further down the line while also providing cleaned water free of microbes and contaminants. We’ll work to design an ozone treatment solution that scales to the size of your storage, ensuring that you’ll end up with treated water and no problems with your equipment.
Learn more about ozone cooling tower water treatment systems and see how you can reduce chemical use, reduce negative environmental impacts and minimize maintenance costs to your cooling towers. Contact Ozone Pure Water today at 800-633-8469 for more information.


The Objective:
Maintain the highest purity of water with the least amount of water waste and chemical use. Chemical use in cooling towers leads to an ever-increasing TDS, which must be reduced by eliminating water (blow down/bleed off), then refilling with raw/lower TDS water. This is a “vicious cycle” that will never end unless one of the TDS increasing culprits is eliminated or reduced: That being “chemicals”.

The Problem:
Cooling Tower water quality tends to be extremely poor. Cooling Tower traditional treatment is based upon extreme chemical use only. This means that you, the “water treatment professional” has a chance to create an entirely new income base, and aid in environmental integrity & responsibility.

I. Water Quality control is difficult due to:
Evaporation rate
Environmental contaminates
Extreme chemical use

II. Chemical Dependence is promoted by an industry that serves and maintains cooling towers.
Most cooling tower manufacturers do nothing about recommending or selling treatment equipment along with the towers. In most cases it’s left up to the end users to set up the treatment method.
The cost of chemicals is lower on the front end than water treatment equipment, but far higher based upon the on going nature of the use.

III. Water Waste:
It’s not uncommon to see a (IE) 3,000-gallon cooling tower continuously draining and replenishing raw water just to lower TDS. This ever-increasing TDS is contributed to a great degree by the chemicals that are used for treatment.

Not only is there an extreme amount of water being wasted on a daily bases, but the environmental impact from the chemical laden wastewater is deplorable. This chemically laden wastewater will eventually make into our lakes, streams, river, and ground water, and is becoming the subject of more stringent EPA regulations.

Ozone Cooling Tower

Advantages Of Using Ozone

  • Bacteria/virus elimination/prevention
  • Organic Build-up elimination/prevention
  • Blow-down reduction/elimination
  • Bleed-off reduction/elimination
  • Improved clarity.
  • Scale reduction.
  • Cooler running temperatures where scale is inhibited or reduced.
  • Reduction or elimination chemicals needed for algae control.

All this with no regularly scheduled maintenance on the ozone unit!


The Ozone Treatment System Is Just 3 Easy Steps

Principle of Operation:
Ozone is injected into the water flow created by a separate circulation pump. This pump pulls the water from the towers sump or basin and sends it to the ozone injection, contact tank, and scale/filtration. Lastly, the treated water returns back to the sump or basin.

The principle is to treat the water and eliminate/reduce the:

  • Scale forming minerals
  • Organics
  • Harmful microbes.

The clean water is then used to clean the entire sump, basin, pipes, and peripheral equipment.

I. Ozone Injection:
Ozone is injected it into the side stream flow. Oxidation starts to take place immediately on microbes, organics, bacteria, and virus.

II. Contact/Mixing Chamber:
A contact tank helps to further the ozone’s ability to oxidize particles allowing them time to react prior to returning to the system. As water flows down the Off Gas Tank, ozonated water rises and mixes any gas in the incoming water.

III. Filtration, Scale Control, Particle Removal:
Possibly the most important aspect of any water treatment is the removal of the particles that have been oxidized. Without this step, all you have done with the ozone is change the structure of the particles by making them larger, insoluble, &/or heavier. This step is necessary for systems that require scale control, and particulate removal.

Ozone Cooling Tower

We are very careful not to construct too large of an ozone unit to handle the bacteria, scale, and algae.

The problem encountered at this point is corrosion. If you carry too high of an ozone residual to de-scale down line you stand a chance of creating a corrosive situation in the sump and its adjacent equipment.

For this reason we have utilized existing water treatment technology and equipment in conjunction with ozonation. The result is a system that works without high maintenance, dangerous chemicals, or costly corrosion.


Ozone Cooling Tower FAQ

How does the maximum service flow rate relate to the total system flow rate?
It doesn’t. It relates to the total system gallonage. Our formula is: total gallons / 4-5 (turnovers per day) / 60 = gpm of the side stream system. This equals approx. 0.004 gpm/gal (treatment gpm / system capacity). Therefore, it’s crucial that we know the total water volume rather than the tonnage. Tonnage to gallon capacity varies greatly per tower manufacturer.

What is the ozone dosage in grams/hr or lbs/day?
Each ozonator produces a set ozone production in gr/hr. The S1 = 1.2 gr/hr; 22HD = 2 gr/hr; 32HD = 3 gr/hr; 62HD = 6 gr/hr; etc. We convert the measurement to lbs/day when over 24 gr/hr. The typical dosage is: 1 gr/hr to every 5 gpm of treated water.
IE: 10 gpm side-stream ozone treatment system would include a 2 gr/hr ozonator (22HD).

Is the ozone flow controlled by the amount of residual in the system or is it wired to the tower pump or system pump control box?
We supply a timer/control box assembly that controls the ozone unit and circulation pump. Operational time will depend upon water and tower conditions. As the conditions improve the operational time can be reduced.

Does the ozone system eliminate the scaling?
Yes, we can design the ozone system to eliminate hardness/scale that can build-up on the tower, piping, pumps, and peripheral equipment. We us a combination of ozone + water softening to eliminate the scaling. This affords a lower cost system by using a smaller ozone unit. Our system is set so the water is not completely soft and will not be corrosive.

Does the ozone system control algae?
Yes, we can design the ozone system to eliminate algae but this denotes a larger ozonator. Algae are plants with roots and are quite resistant to ozone. We can use ozone only, or ozone + a slight chlorine or bromine residual to eliminate algae. The ozone + chlorine or bromine option affords a much lower priced system since the ozone unit used will be much smaller.

Is it true that ozone systems create a corrosive condition?
In the “old days” when ozone was first used on towers corrosion became an issue. This was due to the over use of ozone, or the excessive dosage injected. There are some companies that are still convinced that more is better and ozone can do “everything”. This can lead to costly corrosion problems.

Our philosophy is to use the ozone where it is best suited:

  • Organic inactivation
  • Bacteria, virus, microbe elimination/reduction
  • Clarifying
  • Odor control

For scale and algae control we utilize tried-n-true water treatment equipment that has been successful in all phases of the water treatment industry for over 50 yrs. This affords the use of smaller and less expensive ozone equipment and avoids corrosive conditions.